This issue was fixed in version 1.6.0.
Analysis and contextual insights are available on OpenCVE Cloud.
No vendor fix or workaround currently provided.
Additional remediation guidance may be available on OpenCVE Cloud.
Tracking
Sign in to view the affected projects.
No advisories yet.
Mon, 26 Oct 2026 15:00:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | boneIO Black exposes a Node-RED instance without authentication at the /nodered/ path through a Caddy reverse proxy. The Node-RED Admin API allows deploying flows that can execute arbitrary system commands. An unauthenticated attacker on the local network can deploy a malicious flow to achieve remote code execution and gain full control over the home automation system. This issue was fixed in version 1.6.0. | |
| Title | Missing Authentication for Node-RED in boneIO | |
| First Time appeared |
Boneio
Boneio boneio |
|
| Weaknesses | CWE-306 | |
| CPEs | cpe:2.3:a:boneio:boneio:*:*:*:*:*:*:*:* | |
| Vendors & Products |
Boneio
Boneio boneio |
|
| References |
| |
| Metrics |
cvssV4_0
|
Status: PUBLISHED
Assigner: CERT-PL
Published:
Updated: 2026-10-26T14:45:37.056Z
Reserved: 2026-08-20T09:37:37.786Z
Link: CVE-2026-77052
No data.
Status : Deferred
Published: 2026-10-26T15:16:42.660
Modified: 2026-10-26T17:11:35.487
Link: CVE-2026-77052
No data.
OpenCVE Enrichment
Updated: 2026-10-26T18:50:29Z
-
CWE-306
Missing Authentication for Critical Function