| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of
confidentiality when a malicious user, having physical access, sets the radio in factory default mode where the
product does not correctly initialize all data. |
| CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to
unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious
user, having physical access, sets the radio to the factory default mode. |
| Projects using the SUSE Virtualization (Harvester) environment may expose the OS default ssh login password if they are using the 1.5.x or 1.6.x interactive installer to either create a new cluster or add new hosts to an existing cluster. The environment is not affected if the PXE boot mechanism is utilized along with the Harvester configuration setup. |
| A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow. |
| shadow-utils (aka shadow) 4.4 through 4.17.0 establishes a default /etc/subuid behavior (e.g., uid 100000 through 165535 for the first user account) that can realistically conflict with the uids of users defined on locally administered networks, potentially leading to account takeover, e.g., by leveraging newuidmap for access to an NFS home directory (or same-host resources in the case of remote logins by these local network users). NOTE: it may also be argued that system administrators should not have assigned uids, within local networks, that are within the range that can occur in /etc/subuid. |
| Improper isolation in some Intel(R) Processors stream cache mechanism may allow an authenticated user to potentially enable escalation of privilege via local access. |
| Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges. |
| Enabled IP Forwarding feature in B&R Automation Runtime versions before 6.0.2 may allow remote attack-ers to compromise network security by routing IP-based packets through the host, potentially by-passing firewall, router, or NAC filtering. |
| Insecure default settings have been found in recorder products provided by Yokogawa Electric Corporation. The default setting of the authentication function is disabled on the affected products. Therefore, when connected to a network with default settings, anyone can access all functions related to settings and operations. As a result, an attacker can illegally manipulate and configure important data such as measured values and settings.
This issue affects GX10 / GX20 / GP10 / GP20 Paperless Recorders: R5.04.01 or earlier; GM Data Acquisition System: R5.05.01 or earlier; DX1000 / DX2000 / DX1000N Paperless Recorders: R4.21 or earlier; FX1000 Paperless Recorders: R1.31 or earlier; μR10000 / μR20000 Chart Recorders: R1.51 or earlier; MW100 Data Acquisition Units: All versions; DX1000T / DX2000T Paperless Recorders: All versions; CX1000 / CX2000 Paperless Recorders: All versions. |
| CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an
attacker to execute unauthorized commands when a system’s default password credentials have not been
changed on first use. The default username is not displayed correctly in the WebHMI interface. |
| A remote unauthenticated attacker may use default certificates to generate JWT Tokens and gain full access to the tool and all connected devices. |
| During a short time frame while the device is booting an unauthenticated remote attacker can send traffic to unauthorized networks due to the switch operating in an undefined state until a CPU-induced reset allows proper configuration. |
| CNCF K3s 1.32 before 1.32.4-rc1+k3s1 has a Kubernetes kubelet configuration change with the unintended consequence that, in some situations, ReadOnlyPort is set to 10255. For example, the default behavior of a K3s online installation might allow unauthenticated access to this port, exposing credentials. |
| On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards. |
| Improper isolation of shared resources on a system on a chip by a malicious local attacker with high privileges could potentially lead to a partial loss of integrity. |
| Incorrect configuration of replication security in the MariaDB component of the infra-operator in YAOOK Operator allows an on-path attacker to read database contents, potentially including credentials |
| Improper isolation in the Intel(R) Core(TM) Ultra Processor stream cache mechanism may allow an authenticated user to potentially enable escalation of privilege via local access. |
| Zipkin through 3.5.1 has a /heapdump endpoint (associated with the use of Spring Boot Actuator), a similar issue to CVE-2025-48927. |
| An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs. |
| VMware Aria Operations contains an information disclosure vulnerability. A malicious actor with non-administrative privileges in Aria Operations may exploit this vulnerability to disclose credentials of other users of Aria Operations. |