| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Acronis True Image up to and including version 2017 Build 8053 performs software updates using HTTP. Downloaded updates are only verified using a server-provided MD5 hash. |
| SuperBeam through 4.1.3, when using the LAN or WiFi Direct Share feature, does not use HTTPS or any integrity-protection mechanism for file transfer, which makes it easier for remote attackers to send crafted files, as demonstrated by APK injection. |
| Cast in Google Chrome prior to 57.0.2987.98 for Mac, Windows, and Linux and 57.0.2987.108 for Android sent cookies to sites discovered via SSDP, which allowed an attacker on the local network segment to initiate connections to arbitrary URLs and observe any plaintext cookies sent. |
| KDE KMail does not encrypt attachments in emails when "automatic encryption" is enabled, which allows remote attackers to obtain sensitive information by sniffing the network. |
| Incorrect access control in TP-Link Tapo before v3.1.315 allows attackers to access user credentials in plaintext. |
| An issue was discovered in Sesami Cash Point & Transport Optimizer (CPTO) version 6.3.8.6 (#718), allows remote attackers to obtain sensitive information via transmission of unencrypted, cleartext credentials during Password Reset feature. |
|
IBM Spectrum Protect Plus 10.1.0 through 10.1.12 discloses sensitive information due to unencrypted data being used in the communication flow between Spectrum Protect Plus vSnap and its agents. An attacker could obtain information using main in the middle techniques. IBM X-Force ID: 182106.
|
| Due to usernames/passwords being stored in plaintext in Random Access Memory (RAM), a local, authenticated attacker could gain access to certain credentials, including Windows Logon credentials. |
| Pentaminds CuroVMS v2.0.1 was discovered to contain exposed sensitive information. |
| Insights for Vulnerability Remediation (IVR) is vulnerable to man-in-the-middle attacks that may lead to information disclosure. This requires privileged network access.
|
| The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system. |
| ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files. |
| AVEVA System Platform 2020 stores sensitive information in cleartext, which may allow access to an attacker or a low-privileged user. |
| LRM version 2.4 and lower does not implement TLS encryption. A malicious actor can MITM attack sensitive data in-transit, including credentials. |
| AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72; |
| Any attempt (good or bad) to log into AutomationDirect Stride Field I/O with a web browser may result in the device responding with its password in the communication packets. |
| An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. Cleartext passwords and hashes are exposed through log files. |
| Fresenius Kabi Agilia Link + version 3.0 does not enforce transport layer encryption. Therefore, transmitted data may be sent in cleartext. Transport layer encryption is offered on Port TCP/443, but the affected service does not perform an automated redirect from the unencrypted service on Port TCP/80 to the encrypted service. |
| GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication. |
| Delta Electronics DIAEnergie (Version 1.7.5 and prior) is vulnerable to cleartext transmission as the web application runs by default on HTTP. This could allow an attacker to remotely read transmitted information between the client and product. |