Search Results (823 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-9997 1 Schneider-electric 1 Blmon 2026-04-15 N/A
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.
CVE-2025-13905 1 Schneider-electric 2 Ecostruxure Process Expert, Ecostruxure Process Expert For Aveva System Platform 2026-04-15 N/A
CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.
CVE-2025-8453 1 Schneider-electric 2 Saitel Dp, Saitel Dr 2026-04-15 6.7 Medium
CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation and arbitrary code execution when a privileged engineer user with console access modifies a configuration file used by a root-level daemon to execute custom scripts.
CVE-2024-10498 1 Schneider-electric 1 Powerlogic Hdpm6000 2026-04-15 6.5 Medium
CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in invalid data or loss of web interface functionality.
CVE-2025-54926 1 Schneider-electric 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports 2026-04-15 7.2 High
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed.
CVE-2025-7746 1 Schneider-electric 1 Altivar 2026-04-15 N/A
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser.
CVE-2025-8448 1 Schneider-electric 2 Ecostruxure Building Operation Enterprise Server, Ecostruxure Workstation 2026-04-15 N/A
CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when an attacker is able to capture local SMB traffic between a valid user within the BMS network and the vulnerable products.
CVE-2025-8449 1 Schneider-electric 3 Ecostruxure Building Operation Enterprise Server, Ecostruxure Enterprise Server, Ecostruxure Workstation 2026-04-15 N/A
CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service when an authenticated user sends a specially crafted request to a specific endpoint from within the BMS network.
CVE-2025-11567 1 Schneider-electric 1 Powerchute Serial Shutdown 2026-04-15 N/A
CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.
CVE-2025-11565 1 Schneider-electric 1 Powerchute Serial Shutdown 2026-04-15 N/A
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload.
CVE-2025-54925 1 Schneider-electric 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports 2026-04-15 7.5 High
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url.
CVE-2025-54927 1 Schneider-electric 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports 2026-04-15 4.9 Medium
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized access to sensitive files when an authenticated attackers uses a crafted path input that is processed by the system.
CVE-2025-13901 1 Schneider-electric 7 Modicon M241, Modicon M241/m251, Modicon M241 Firmware and 4 more 2026-03-11 5.3 Medium
CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.
CVE-2025-13957 1 Schneider-electric 1 Struxureware Data Center Expert 2026-03-11 N/A
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default.
CVE-2025-11739 1 Schneider-electric 3 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation, Ecostruxure Power Operation With Advanced Reporting And Dashboards 2026-03-11 7.8 High
CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.
CVE-2025-13902 1 Schneider-electric 10 Modicon Controllers M241/m251, Modicon Controllers M258/lmc058, Modicon Lmc058 and 7 more 2026-03-11 5.4 Medium
CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload.
CVE-2025-13844 1 Schneider-electric 1 Ecostruxure Power Build - Rapsody 2026-03-03 5.3 Medium
CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody.
CVE-2023-6407 2 Microsoft, Schneider-electric 6 Windows 10 1507, Windows 11 21h2, Windows Server 2016 and 3 more 2026-02-25 5.3 Medium
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local and low-privileged attacker.
CVE-2018-1124 6 Canonical, Debian, Opensuse and 3 more 13 Ubuntu Linux, Debian Linux, Leap and 10 more 2025-12-18 7.8 High
procps-ng before version 3.3.15 is vulnerable to multiple integer overflows leading to a heap corruption in file2strvec function. This allows a privilege escalation for a local attacker who can create entries in procfs by starting processes, which could result in crashes or arbitrary code execution in proc utilities run by other users.
CVE-2018-1126 5 Canonical, Debian, Procps-ng Project and 2 more 13 Ubuntu Linux, Debian Linux, Procps-ng and 10 more 2025-12-17 N/A
procps-ng before version 3.3.15 is vulnerable to an incorrect integer size in proc/alloc.* leading to truncation/integer overflow issues. This flaw is related to CVE-2018-1124.