Search Results (2353 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2015-6675 1 Siemens 1 Ruggedcom Rugged Operating System 2025-04-12 N/A
Siemens RUGGEDCOM ROS 3.8.0 through 4.1.x permanently enables the IP forwarding feature, which allows remote attackers to bypass a VLAN isolation protection mechanism via IP traffic.
CVE-2016-4954 5 Ntp, Opensuse, Oracle and 2 more 15 Ntp, Leap, Opensuse and 12 more 2025-04-12 7.5 High
The process_packet function in ntp_proto.c in ntpd in NTP 4.x before 4.2.8p8 allows remote attackers to cause a denial of service (peer-variable modification) by sending spoofed packets from many source IP addresses in a certain scenario, as demonstrated by triggering an incorrect leap indication.
CVE-2016-6204 1 Siemens 1 Sinema Remote Connect Server 2025-04-12 N/A
Cross-site scripting (XSS) vulnerability in the integrated web server in Siemens SINEMA Remote Connect Server before 1.2 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
CVE-2016-5874 1 Siemens 1 Simatic Net Pc-software 2025-04-12 N/A
Siemens SIMATIC NET PC-Software before 13 SP2 allows remote attackers to cause a denial of service (OPC UA service outage) via crafted TCP packets.
CVE-2016-5849 1 Siemens 1 Sicam Pas\/pqs 2025-04-12 2.5 Low
Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage.
CVE-2016-5848 1 Siemens 1 Sicam Pas\/pqs 2025-04-12 6.7 Medium
Siemens SICAM PAS before 8.07 does not properly restrict password data in the database, which makes it easier for local users to calculate passwords by leveraging unspecified database privileges.
CVE-2016-4956 6 Novell, Ntp, Opensuse and 3 more 11 Suse Manager, Ntp, Leap and 8 more 2025-04-12 5.3 Medium
ntpd in NTP 4.x before 4.2.8p8 allows remote attackers to cause a denial of service (interleaved-mode transition and time change) via a spoofed broadcast packet. NOTE: this vulnerability exists because of an incomplete fix for CVE-2016-1548.
CVE-2016-5744 1 Siemens 1 Simatic Wincc 2025-04-12 N/A
Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted packets.
CVE-2012-3009 1 Siemens 1 Comos 2025-04-11 N/A
Siemens COMOS before 9.1 Patch 413, 9.2 before Update 03 Patch 023, and 10.0 before Patch 005 allows remote authenticated users to obtain database administrative access via unspecified method calls.
CVE-2012-2598 1 Siemens 1 Wincc 2025-04-11 N/A
Buffer overflow in the DiagAgent web server in Siemens WinCC 7.0 SP3 through Update 2 allows remote attackers to cause a denial of service (agent outage) via crafted input.
CVE-2012-2597 1 Siemens 1 Wincc 2025-04-11 N/A
Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL.
CVE-2012-2441 1 Siemens 1 Ruggedcom Rugged Operating System 2025-04-11 N/A
RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH or (2) HTTPS session, a different vulnerability than CVE-2012-1803.
CVE-2012-1799 1 Siemens 4 Scalance S602, Scalance S612, Scalance S613 and 1 more 2025-04-11 N/A
The web server on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 does not limit the rate of authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack on the administrative password.
CVE-2012-1800 1 Siemens 4 Scalance S602, Scalance S612, Scalance S613 and 1 more 2025-04-11 N/A
Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute arbitrary code via a crafted DCP frame.
CVE-2011-4879 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2025-04-11 N/A
miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.
CVE-2013-6840 1 Siemens 1 Comos 2025-04-11 N/A
Siemens COMOS before 9.2.0.8.1, 10.0 before 10.0.3.1.40, and 10.1 before 10.1.0.0.2 allows local users to gain database privileges via unspecified vectors.
CVE-2012-1802 1 Siemens 10 Scalance X-300, Scalance X-300 Firmware, Scalance X-300eec and 7 more 2025-04-11 N/A
Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.
CVE-2011-4878 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2025-04-11 N/A
Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI.
CVE-2011-4877 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2025-04-11 N/A
HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP.
CVE-2013-4651 1 Siemens 17 Scalance W700 Series Firmware, Scalance W744-1, Scalance W744-1pro and 14 more 2025-04-11 N/A
Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate's trust relationship.