Search Results (125 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-8731 1 Trendnet 3 Ti-g160i, Ti-pg102i, Tpl-430ap 2026-04-15 9.8 Critical
A vulnerability was identified in TRENDnet TI-G160i, TI-PG102i and TPL-430AP up to 20250724. This affects an unknown part of the component SSH Service. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The vendor explains: "For product TI-PG102i and TI-G160i, by default, the product's remote management options are all disabled. The root account is for troubleshooting purpose and the password is encrypted. However, we will remove the root account from the next firmware release. For product TPL-430AP, the initial setup process requires user to set the password for the management GUI. Once that was done, the default password will be invalid."
CVE-2024-30210 2026-04-15 7.4 High
IO-1020 Micro ELD uses a default WIFI password that could allow an adjacent attacker to connect to the device.
CVE-2024-12286 2026-04-15 9.8 Critical
MOBATIME Network Master Clock - DTS 4801 allows attackers to use SSH to gain initial access using default credentials.
CVE-2022-50803 2026-04-15 9.8 Critical
JM-DATA ONU JF511-TV version 1.0.67 uses default credentials that allow attackers to gain unauthorized access to the device with administrative privileges.
CVE-2025-54756 1 Brightsign 2 Brightsign Os Series 4 Players, Brightsign Os Series 5 Players 2026-04-15 8.4 High
BrightSign players running BrightSign OS series 4 prior to v8.5.53.1 or series 5 prior to v9.0.166 use a default password that is guessable with knowledge of the device information. The latest release fixes this issue for new installations; users of old installations are encouraged to change all default passwords.
CVE-2024-5632 2026-04-15 N/A
Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, create a WiFi network with a default password. A user is neither advised to change it during the installation process, nor such a need is described in the manual. As the cameras from the same kit connect automatically, it is very probable for the default password to be left unchanged.
CVE-2024-12013 2026-04-15 7.6 High
A CWE-1392 “Use of Default Credentials” was discovered affecting the 130.8005 TCP/IP Gateway running firmware version 12h. The device exposes an FTP server with default and easy-to-guess admin credentials. A remote attacker capable of interacting with the FTP server could gain access and perform changes over resources exposed by the service such as configuration files where password hashes are saved or where network settings are stored.
CVE-2024-13893 2026-04-15 N/A
Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, might share same credentials for telnet service. Hash of the password can be retrieved through physical access to SPI connected memory. For the telnet service to be enabled, the inserted SD card needs to have a folder with a specific name created.  Two products were tested, but since the vendor has not replied to reports, patching status remains unknown, as well as groups of devices and firmware ranges in which the same password is shared. Newer firmware versions might be vulnerable as well.
CVE-2024-28093 1 Adtran 1 Netvanta 3120 Firmware 2026-04-15 8.8 High
The TELNET service of AdTran NetVanta 3120 18.01.01.00.E devices is enabled by default, and has default credentials for a root-level account.
CVE-2024-31069 2026-04-15 7.4 High
IO-1020 Micro ELD web server uses a default password for authentication.
CVE-2024-4622 2026-04-15 N/A
If misconfigured, alpitronic Hypercharger EV charging devices can expose a web interface protected by authentication. If the default credentials are not changed, an attacker can use public knowledge to access the device as an administrator.
CVE-2025-6951 1 Safecam 1 X300 2026-04-15 4.3 Medium
A vulnerability classified as problematic was found in SAFECAM X300 up to 20250611. This vulnerability affects unknown code of the component FTP Service. The manipulation leads to use of default credentials. Access to the local network is required for this attack to succeed. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-6245 2026-04-15 7.4 High
Use of Default Credentials vulnerability in Maruti Suzuki SmartPlay on Linux (Infotainment Hub modules) allows attacker to try common or default usernames and passwords.The issue was detected on a 2022 Maruti Suzuki Brezza in India Market. This issue affects SmartPlay: 66T0.05.50.
CVE-2025-1531 2026-04-15 6.5 Medium
Authentication credentials leakage vulnerability in Hitachi Ops Center Analyzer viewpoint.This issue affects Hitachi Ops Center Analyzer viewpoint: from 10.0.0-00 before 11.0.4-00.
CVE-2021-47707 1 Commax 1 Cvd-axx Dvr 2026-04-15 N/A
COMMAX CVD-Axx DVR 5.1.4 contains weak default administrative credentials that allow remote password attacks and disclose RTSP stream. Attackers can exploit this by sending a POST request with the 'passkey' parameter set to '1234', allowing them to access the web control panel.
CVE-2025-10678 1 Netbirdio 1 Netbird 2026-04-15 N/A
NetBird VPN when installed using vendor's provided script failed to remove or change default password of an admin account created by ZITADEL. This issue affects instances installed using vendor's provided script. This issue may affect instances created with Docker if the default password was not changed nor the user was removed. This issue has been fixed in version 0.57.0
CVE-2025-29525 1 Dasan 1 H660wm 2026-04-15 5.3 Medium
DASAN GPON ONU H660WM OS version H660WMR210825 Hardware version DS-E5-583-A1 was discovered to contain insecure default credentials in the modem's control panel.
CVE-2024-10476 2026-04-15 8 High
Default credentials are used in the above listed BD Diagnostic Solutions products. If exploited, threat actors may be able to access, modify or delete data, including sensitive information such as protected health information (PHI) and personally identifiable information (PII). Exploitation of this vulnerability may allow an attacker to shut down or otherwise impact the availability of the system. Note: BD Synapsys™ Informatics Solution is only in scope of this vulnerability when installed on a NUC server. BD Synapsys™ Informatics Solution installed on a customer-provided virtual machine or on the BD Kiestra™ SCU hardware is not in scope.
CVE-2024-54015 2026-04-15 7.5 High
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials.
CVE-2025-2341 2026-04-15 3.1 Low
A vulnerability was found in IROAD Dash Cam X5 up to 20250203. It has been rated as problematic. This issue affects some unknown processing of the component SSID. The manipulation leads to use of default credentials. The attack needs to be initiated within the local network. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.