| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems. |
| A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges. |
| The Chirp Access app contains a hard-coded password, BEACON_PASSWORD. An attacker within Bluetooth range could change configuration settings within the Bluetooth beacon, effectively disabling the application's ability to notify users when they are near a Beacon-enabled access point. This variable cannot be used to change the configuration settings of the door readers or locksets and does not affect the ability for authorized users of the mobile application to lock or unlock access points. |
| setuid() does not affect libuv's internal io_uring operations if initialized before the call to setuid().
This allows the process to perform privileged operations despite presumably having dropped such privileges through a call to setuid().
This vulnerability affects all users using version greater or equal than Node.js 18.18.0, Node.js 20.4.0 and Node.js 21. |
| IBM Common Cryptographic Architecture (CCA) 7.5.52 and 8.4.82 could allow an unauthenticated user to execute arbitrary commands with elevated privileges on the system. |
| Toshiba printers use SNMP for configuration. Using the private community, it is possible to remotely execute commands as root on the remote printer. Using this vulnerability will allow any attacker to get a root access on a remote Toshiba printer. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |
| The Toshiba printers are vulnerable to a Local Privilege Escalation vulnerability. An attacker can remotely compromise any Toshiba printer. As for the affected products/models/versions, see the reference URL. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices store user passwords in plaintext without proper protection. This could allow a physical attacker to retrieve them from the embedded storage ICs. |
| An issue in Solar-Log 1000 before v2.8.2 and build 52-23.04.2013 was discovered to store plaintext passwords in the export.html, email.html, and sms.html files -- fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base. |
| Minecraft RCON Terminal is a VS Code extension that streamlines Minecraft server management. Versions 0.1.0 through 2.0.6 stores passwords using VS Code's configuration API which writes to settings.json in plaintext. This issue is fixed in version 2.1.0. |
| A vulnerability in APIML Spring Cloud Gateway which leverages user privileges by unexpected signing proxied request by Zowe's client certificate. This allows access to a user to the endpoints requiring an internal client certificate without any credentials. It could lead to managing components in there and allow an attacker to handle the whole communication including user credentials. |
| A vulnerability was found in shsuishang ShopSuite ModulithShop up to 45a99398cec3b7ad7ff9383694f0b53339f2d35a. Affected by this issue is some unknown functionality of the component RSA/OAuth2/Database. The manipulation results in hard-coded credentials. The attack can be executed remotely. The exploit has been made public and could be used. This product implements a rolling release for ongoing delivery, which means version information for affected or updated releases is unavailable. |
| The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS. |
| Clash Verge Rev thru 2.2.3 (fixed in 2.3.0) forces the installation of system services(clash-verge-service) by default and exposes key functions through the unauthorized HTTP API `/start_clash`, allowing local users to submit arbitrary bin_path parameters and pass them directly to the service process for execution, resulting in local privilege escalation. |
| An attacker with adjacent access, without authentication, can exploit
this vulnerability to retrieve a hard-coded password embedded in
publicly available software. This password can then be used to decrypt
sensitive network traffic, affecting the Cognex device. |
| Unchecked return value in SDM firmware for Intel(R) Stratix 10 and Intel(R) Agilex 7 FPGAs before version 23.3 may allow an authenticated user to potentially enable denial of service via adjacent access. |
| Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 |
| A vulnerability was found in saltbo zpan up to 1.6.5/1.7.0-beta2. It has been rated as problematic. This issue affects the function NewToken of the file zpan/internal/app/service/token.go of the component JSON Web Token Handler. The manipulation with the input 123 leads to use of hard-coded password. The attack may be initiated remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. |
| HCL Workload Scheduler stores user credentials in plain text which can be read by a local user. |
| DYMO LabelWriter Print Server through 2.366 contains a backdoor hard-coded password that could allow an attacker to take control. |