| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Dependency-Track is a component analysis platform that allows organizations to identify and reduce risk in the software supply chain. Prior to version 4.13.5, Dependency-Track may send credentials meant for a private NuGet repository to `api.nuget.org` via the HTTP `Authorization` header, and may disclose names and versions of components marked as internal to `api.nuget.org`. This can happen if the Dependency-Track instance contains .NET components, a custom NuGet repository has been configured, the custom repository has been configured with authentication credentials, and the repository server does not provide `PackageBaseAddress` resource in its service index. The issue has been fixed in Dependency-Track 4.13.5. Some workarounds are avaialble. Disable custom NuGet repositories until the patch has been applied, invalidate the previously used credentials, and generate new credentials for usage after the patch has been applied. |
| Seth Fogie, member of the AXIS Camera Station Pro Bug Bounty Program, has found that the Incident report feature may expose sensitive credentials on the AXIS Camera Station windows client. If Incident report is not being used with credentials configured this flaw does not apply.
Axis has released patched versions for the highlighted flaw. Please refer to the Axis security advisory for more information and solution. |
| Information Exposure vulnerability in Hitachi JP1/IT Desktop Management 2 - Smart Device Manager on Windows.This issue affects JP1/IT Desktop Management 2 - Smart Device Manager: from 12-00 before 12-00-08, from 11-10 through 11-10-08, from 11-00 through 11-00-05, from 10-50 through 10-50-06. |
| EasyFlow GP developed by Digiwin has an Insufficiently Protected Credentials vulnerability, allowing privileged remote attackers to obtain plaintext credentials of AD and system mail from the system frontend. |
| EasyFlow GP developed by Digiwin has an Insufficiently Protected Credentials vulnerability, allowing privileged remote attackers to obtain plaintext database account credentials from the system frontend. |
| GRAU DATA Blocky before 3.1 stores passwords encrypted rather than hashed. At the login screen, the user's password is compared to the user's decrypted cleartext password. An attacker with Windows admin or debugging rights can therefore steal the user's Blocky password and from there impersonate that local user. |
| A flaw has been found in Mangati NovoSGA up to 2.2.12. The impacted element is an unknown function of the file /novosga.users/new of the component User Creation Page. Executing manipulation of the argument Senha/Confirmação da senha can lead to weak password requirements. The attack can be launched remotely. Attacks of this nature are highly complex. The exploitability is regarded as difficult. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability has been identified in the way that Rancher stores vSphere's CPI (Cloud Provider Interface) and CSI (Container Storage Interface) credentials used to deploy clusters through the vSphere cloud provider. This issue leads to the vSphere CPI and CSI passwords being stored in a plaintext object inside Rancher. This vulnerability is only applicable to users that deploy clusters in vSphere environments. |
| The product transmits or stores authentication credentials, but it uses an insecure method that is susceptible to unauthorized interception and/or retrieval. (CWE-522)
Hitachi Vantara Pentaho Data Integration & Analytics versions before 10.2.0.0 and 9.3.0.8, including 8.3.x, discloses database passwords when saving connections to RedShift.
Products must not disclose sensitive information without cause. Disclosure of sensitive information can lead to further exploitation. |
| No password for the root user is set in Novakon P series. This allows phyiscal attackers to enter the console easily.
This issue affects P series: P – V2001.A.C518o2 until P-2.0.05 Build
2026.02.06 (commit d0f97fd9). |
| A vulnerability has been identified in the NeuVector scanner where the scanner process accepts registry and controller credentials as command-line arguments, potentially exposing sensitive credentials to local users. |
| A 3rd-party component exposed its password in process arguments, allowing for low-privileged users to access it. |
| The /WmAdmin/,/invoke/vm.server/login login page in the Integration Server in Software AG webMethods 10.15.0 before Core_Fix7 allows remote attackers to reach the administration panel and discover hostname and version information by sending an arbitrary username and a blank password to the /WmAdmin/#/login/ URI. |
| GenX_FX is an advance IA trading platform that will focus on forex trading. A vulnerability was identified in the GenX FX backend where API keys and authentication tokens may be exposed if environment variables are misconfigured. Unauthorized users could gain access to cloud resources (Google Cloud, Firebase, GitHub, etc.). |
| An information disclosure flaw was found in OpenShift's internal image registry operator. The AZURE_CLIENT_SECRET can be exposed through an environment variable defined in the pod definition, but is limited to Azure environments. An attacker controlling an account that has high enough permissions to obtain pod information from the openshift-image-registry namespace could use this obtained client secret to perform actions as the registry operator's Azure service account. |
| When a user logs in via SAP Business One native client, the SLD backend service fails to enforce proper encryption of certain APIs. This leads to exposure of sensitive credentials within http response body. As a result, it has a high impact on the confidentiality, integrity, and availability of the application. |
| H3C ER8300G2-X is vulnerable to Incorrect Access Control. The password for the router's management system can be accessed via the management system page login interface. |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Report Clients do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role. |
| A passback vulnerability which relates to office/small office multifunction printers and laser printers. |
| A passback vulnerability which relates to production printers and office multifunction printers. |