Export limit exceeded: 405187 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (978 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2017-10615 | 1 Juniper | 17 Ex3200, Ex3300, Ex3300-vc and 14 more | 2025-04-20 | N/A |
| A vulnerability in the pluggable authentication module (PAM) of Juniper Networks Junos OS may allow an unauthenticated network based attacker to potentially execute arbitrary code or crash daemons such as telnetd or sshd that make use of PAM. Affected Juniper Networks Junos OS releases are: 14.1 from 14.1R5 prior to 14.1R8-S4, 14.1R9; 14.1X53 prior to 14.1X53-D50 on EX and QFX series; 14.2 from 14.2R3 prior to 14.2R7-S8, 14.2R8; No other Junos OS releases are affected by this issue. No other Juniper Networks products are affected by this issue. | ||||
| CVE-2017-10618 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| When the 'bgp-error-tolerance' feature â€" designed to help mitigate remote session resets from malformed path attributes â€" is enabled, a BGP UPDATE containing a specifically crafted set of transitive attributes can cause the RPD routing process to crash and restart. Devices with BGP enabled that do not have 'bgp-error-tolerance' configured are not vulnerable to this issue. Affected releases are Juniper Networks Junos OS 13.3 prior to 13.3R10-S2; 14.1 prior to 14.1R8-S4, 14.1R9; 14.1X50 prior to 14.1X50-D185; 14.1X53 prior to 14.1X53-D45, 14.1X53-D50; 14.2 prior to 14.2R7-S7, 14.2R8; 15.1 prior to 15.1F5-S8, 15.1F6-S7, 15.1R5-S6, 15.1R6-S2, 15.1R7; 15.1X49 prior to 15.1X49-D100; 15.1X53 prior to 15.1X53-D64, 15.1X53-D70; 16.1 prior to 16.1R3-S4, 16.1R4-S3, 16.1R5; 16.2 prior to 16.2R1-S5, 16.2R2; 17.1 prior to 17.1R1-S3, 17.1R2; 17.2 prior to 17.2R1-S2, 17.2R2; 17.2X75 prior to 17.2X75-D50. No other Juniper Networks products or platforms are affected by this issue. | ||||
| CVE-2017-10610 | 1 Juniper | 2 Junos, Srx Series | 2025-04-20 | N/A |
| On SRX Series devices, a crafted ICMP packet embedded within a NAT64 IPv6 to IPv4 tunnel may cause the flowd process to crash. Repeated crashes of the flowd process constitutes an extended denial of service condition for the SRX Series device. This issue only occurs if NAT64 is configured. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D71, 12.3X48 prior to 12.3X48-D55, 15.1X49 prior to 15.1X49-D100 on SRX Series. No other Juniper Networks products or platforms are affected by this issue. | ||||
| CVE-2017-10613 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| A vulnerability in a specific loopback filter action command, processed in a specific logical order of operation, in a running configuration of Juniper Networks Junos OS, allows an attacker with CLI access and the ability to initiate remote sessions to the loopback interface with the defined action, to hang the kernel. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D55; 12.3X48 prior to 12.3X48-D35; 14.1 prior to 14.1R8-S4, 14.1R9; 14.1X53 prior to 14.1X53-D40; 14.2 prior to 14.2R4-S9, 14.2R7-S8, 14.2R8; 15.1 prior to 15.1F5-S3, 15.1F6, 15.1R4; 15.1X49 prior to 15.1X49-D60; 15.1X53 prior to 15.1X53-D47; 16.1 prior to 16.1R2. No other Juniper Networks products or platforms are affected by this issue. | ||||
| CVE-2017-2307 | 1 Juniper | 1 Junos Space | 2025-04-20 | N/A |
| A reflected cross site scripting vulnerability in the administrative interface of Juniper Networks Junos Space versions prior to 16.1R1 may allow remote attackers to steal sensitive information or perform certain administrative actions on Junos Space. | ||||
| CVE-2017-10621 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| A denial of service vulnerability in telnetd service on Juniper Networks Junos OS allows remote unauthenticated attackers to cause a denial of service. Affected Junos OS releases are: 12.1X46 prior to 12.1X46-D71; 12.3X48 prior to 12.3X48-D50; 14.1 prior to 14.1R8-S5, 14.1R9; 14.1X53 prior to 14.1X53-D50; 14.2 prior to 14.2R7-S9, 14.2R8; 15.1 prior to 15.1F2-S16, 15.1F5-S7, 15.1F6-S6, 15.1R5-S2, 15.1R6; 15.1X49 prior to 15.1X49-D90; 15.1X53 prior to 15.1X53-D47; 16.1 prior to 16.1R4-S1, 16.1R5; 16.2 prior to 16.2R1-S3, 16.2R2; | ||||
| CVE-2017-10620 | 1 Juniper | 21 Junos, Srx100, Srx110 and 18 more | 2025-04-20 | N/A |
| Juniper Networks Junos OS on SRX series devices do not verify the HTTPS server certificate before downloading anti-virus updates. This may allow a man-in-the-middle attacker to inject bogus signatures to cause service disruptions or make the device not detect certain types of attacks. Affected Junos OS releases are: 12.1X46 prior to 12.1X46-D71; 12.3X48 prior to 12.3X48-D55; 15.1X49 prior to 15.1X49-D110; | ||||
| CVE-2017-10619 | 1 Juniper | 7 Junos, Srx1400, Srx3400 and 4 more | 2025-04-20 | N/A |
| When Express Path (formerly known as service offloading) is configured on Juniper Networks SRX1400, SRX3400, SRX3600, SRX5400, SRX5600, SRX5800 in high availability cluster configuration mode, certain multicast packets might cause the flowd process to crash, halting or interrupting traffic from flowing through the device and triggering RG1+ (data-plane) fail-over to the secondary node. Repeated crashes of the flowd process may constitute an extended denial of service condition. This service is not enabled by default and is only supported in high-end SRX platforms. Affected releases are Juniper Networks Junos OS 12.3X48 prior to 12.3X48-D45, 15.1X49 prior to 15.1X49-D80 on SRX1400, SRX3400, SRX3600, SRX5400, SRX5600, SRX5800. | ||||
| CVE-2017-10608 | 1 Juniper | 13 Junos, Srx110, Srx1400 and 10 more | 2025-04-20 | N/A |
| Any Juniper Networks SRX series device with one or more ALGs enabled may experience a flowd crash when traffic is processed by the Sun/MS-RPC ALGs. This vulnerability in the Sun/MS-RPC ALG services component of Junos OS allows an attacker to cause a repeated denial of service against the target. Repeated traffic in a cluster may cause repeated flip-flop failure operations or full failure to the flowd daemon halting traffic on all nodes. Only IPv6 traffic is affected by this issue. IPv4 traffic is unaffected. This issues is not seen with to-host traffic. This issue has no relation with HA services themselves, only the ALG service. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D55 on SRX; 12.1X47 prior to 12.1X47-D45 on SRX; 12.3X48 prior to 12.3X48-D32, 12.3X48-D35 on SRX; 15.1X49 prior to 15.1X49-D60 on SRX. | ||||
| CVE-2017-10612 | 1 Juniper | 1 Junos Space | 2025-04-20 | N/A |
| A persistent site scripting vulnerability in Juniper Networks Junos Space allows users who can change certain configuration to implant malicious Javascript or HTML which may be used to steal information or perform actions as other Junos Space users or administrators. Affected releases are Juniper Networks Junos Space all versions prior to 17.1R1. | ||||
| CVE-2017-10603 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| An XML injection vulnerability in Junos OS CLI can allow a locally authenticated user to elevate privileges and run arbitrary commands as the root user. This issue was found during internal product security testing. Affected releases are Juniper Networks Junos OS 15.1X53 prior to 15.1X53-D47, 15.1 prior to 15.1R3. Junos versions prior to 15.1 are not affected. No other Juniper Networks products or platforms are affected by this issue. | ||||
| CVE-2017-10602 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| A buffer overflow vulnerability in Junos OS CLI may allow a local authenticated user with read only privileges and access to Junos CLI, to execute code with root privileges. Affected releases are Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D46 on EX2200/VC, EX3200, EX3300/VC, EX4200, EX4300, EX4550/VC, EX4600, EX6200, EX8200/VC (XRE), QFX3500, QFX3600, QFX5100; 14.1X53 versions prior to 14.1X53-D130 on QFabric System; 14.2 versions prior to 14.2R4-S9, 14.2R6; 15.1 versions prior to 15.1F5, 15.1R3; 15.1X49 versions prior to 15.1X49-D40 on SRX Series; 15.1X53 versions prior to 15.1X53-D47 on NFX150, NFX250; 15.1X53 versions prior to 15.1X53-D65 on QFX10000 Series; 15.1X53 versions prior to 15.1X53-D233 on QFX5110, QFX5200. | ||||
| CVE-2017-10624 | 1 Juniper | 1 Junos Space | 2025-04-20 | N/A |
| Insufficient verification of node certificates in Juniper Networks Junos Space may allow a man-in-the-middle type of attacker to make unauthorized modifications to Space database or add nodes. Affected releases are Juniper Networks Junos Space all versions prior to 17.1R1. | ||||
| CVE-2017-10623 | 1 Juniper | 1 Junos Space | 2025-04-20 | N/A |
| Lack of authentication and authorization of cluster messages in Juniper Networks Junos Space may allow a man-in-the-middle type of attacker to intercept, inject or disrupt Junos Space cluster operations between two nodes. Affected releases are Juniper Networks Junos Space all versions prior to 17.1R1. | ||||
| CVE-2017-10622 | 1 Juniper | 1 Junos Space | 2025-04-20 | N/A |
| An authentication bypass vulnerability in Juniper Networks Junos Space Network Management Platform may allow a remote unauthenticated network based attacker to login as any privileged user. This issue only affects Junos Space Network Management Platform 17.1R1 without Patch v1 and 16.1 releases prior to 16.1R3. This issue was found by an external security researcher. | ||||
| CVE-2016-4929 | 1 Juniper | 1 Junos Space | 2025-04-20 | N/A |
| Command injection vulnerability in Junos Space before 15.2R2 allows attackers to execute arbitrary code as a root user. | ||||
| CVE-2016-4925 | 1 Juniper | 1 Junose | 2025-04-20 | N/A |
| Receipt of a specifically malformed IPv6 packet processed by the router may trigger a line card reset: processor exception 0x68616c74 (halt) in task: scheduler. The line card will reboot and recover without user interaction. However, additional specifically malformed packets may cause follow-on line card resets and lead to an extended service outage. This issue only affects E Series routers with IPv6 licensed and enabled. Routers not configured to process IPv6 traffic are unaffected by this vulnerability. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. No other Juniper Networks products or platforms are affected by this issue. | ||||
| CVE-2016-4924 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| An incorrect permissions vulnerability in Juniper Networks Junos OS on vMX may allow local unprivileged users on a host system read access to vMX or vPFE images and obtain sensitive information contained in them such as private cryptographic keys. This issue was found during internal product security testing. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 15.1 prior to 15.1F5; 14.1 prior to 14.1R8 | ||||
| CVE-2017-2301 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| On Juniper Networks products or platforms running Junos OS 11.4 prior to 11.4R13-S3, 12.1X46 prior to 12.1X46-D60, 12.3 prior to 12.3R12-S2 or 12.3R13, 12.3X48 prior to 12.3X48-D40, 13.2X51 prior to 13.2X51-D40, 13.3 prior to 13.3R10, 14.1 prior to 14.1R8, 14.1X53 prior to 14.1X53-D12 or 14.1X53-D35, 14.1X55 prior to 14.1X55-D35, 14.2 prior to 14.2R7, 15.1 prior to 15.1F6 or 15.1R3, 15.1X49 prior to 15.1X49-D60, 15.1X53 prior to 15.1X53-D30 and DHCPv6 enabled, when a crafted DHCPv6 packet is received from a subscriber, jdhcpd daemon crashes and restarts. Repeated crashes of the jdhcpd process may constitute an extended denial of service condition for subscribers attempting to obtain IPv6 addresses. | ||||
| CVE-2017-10605 | 1 Juniper | 14 Junos, Srx100, Srx110 and 11 more | 2025-04-20 | N/A |
| On all vSRX and SRX Series devices, when the DHCP or DHCP relay is configured, specially crafted packet might cause the flowd process to crash, halting or interrupting traffic from flowing through the device(s). Repeated crashes of the flowd process may constitute an extended denial of service condition for the device(s). If the device is configured in high-availability, the RG1+ (data-plane) will fail-over to the secondary node. If the device is configured in stand-alone, there will be temporary traffic interruption until the flowd process is restored automatically. Sustained crafted packets may cause the secondary failover node to fail back, or fail completely, potentially halting flowd on both nodes of the cluster or causing flip-flop failovers to occur. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67 on vSRX or SRX Series; 12.3X48 prior to 12.3X48-D50 on vSRX or SRX Series; 15.1X49 prior to 15.1X49-D91, 15.1X49-D100 on vSRX or SRX Series. | ||||