Search Results (2335 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-33023 1 Siemens 11 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000re, Ruggedcom Rox Rx1400 and 8 more 2026-04-15 4.1 Medium
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions), RUGGEDCOM ROX MX5000RE (All versions), RUGGEDCOM ROX RX1400 (All versions), RUGGEDCOM ROX RX1500 (All versions), RUGGEDCOM ROX RX1501 (All versions), RUGGEDCOM ROX RX1510 (All versions), RUGGEDCOM ROX RX1511 (All versions), RUGGEDCOM ROX RX1512 (All versions), RUGGEDCOM ROX RX1524 (All versions), RUGGEDCOM ROX RX1536 (All versions), RUGGEDCOM ROX RX5000 (All versions). The affected devices do not properly enforce the restriction of files that can be uploaded from the web interface. This could allow an authenticated remote attacker with high privileges in the web interface to upload arbitrary files.
CVE-2024-31485 1 Siemens 2 Cpci85 Firmware, Sicore Base System 2026-04-15 7.2 High
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.30), SICORE Base system (All versions < V1.3.0). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
CVE-2024-33498 1 Siemens 1 Simatic Rtls Locating Manager 2026-04-15 5.3 Medium
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected applications do not properly release memory that is allocated when handling specifically crafted incoming packets. This could allow an unauthenticated remote attacker to cause a denial of service condition by crashing the service when it runs out of memory. The service is restarted automatically after a short time.
CVE-2025-40744 1 Siemens 1 Solid Edge Se2025 2026-04-15 7.5 High
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 11). Affected applications do not properly validate client certificates to connect to License Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks.
CVE-2024-33495 1 Siemens 1 Simatic Rtls Locating Manager 2026-04-15 6.5 Medium
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected application does not properly limit the size of specific logs. This could allow an unauthenticated remote attacker to exhaust system resources by creating a great number of log entries which could potentially lead to a denial of service condition. A successful exploitation requires the attacker to have access to specific SIMATIC RTLS Locating Manager Clients in the deployment.
CVE-2024-33494 1 Siemens 1 Simatic Rtls Locating Manager 2026-04-15 6.5 Medium
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected components do not properly authenticate heartbeat messages. This could allow an unauthenticated remote attacker to affected the availability of secondary RTLS systems configured using a TeeRevProxy service and potentially cause loss of data generated during the time the attack is ongoing.
CVE-2025-40760 1 Siemens 1 Altair Grid Engine 2026-04-15 5.5 Medium
A vulnerability has been identified in Altair Grid Engine (All versions < V2026.0.0). Affected products do not properly handle error messages and discloses sensitive password hash information when processing user authentication requests. This could allow a local attacker to extract password hashes for privileged accounts, which can then be subjected to offline brute-force attacks.
CVE-2024-39888 1 Siemens 1 Mendix Encryption 2026-04-15 7.5 High
A vulnerability has been identified in Mendix Encryption (All versions >= V10.0.0 < V10.0.2). Affected versions of the module define a specific hard-coded default value for the EncryptionKey constant, which is used in projects where no individual EncryptionKey was specified. This could allow to an attacker to decrypt any encrypted project data, as the default encryption key can be considered compromised.
CVE-2023-52238 1 Siemens 2 Ruggedcom Rst2228, Ruggedcom Rst2228p 2026-04-15 4.3 Medium
A vulnerability has been identified in RUGGEDCOM RST2228 (All versions < V5.9.0), RUGGEDCOM RST2228P (All versions < V5.9.0). The web server of the affected systems leaks the MACSEC key in clear text to a logged in user. An attacker with the credentials of a low privileged user could retrieve the MACSEC key and access (decrypt) the ethernet frames sent by authorized recipients.
CVE-2023-49069 1 Siemens 1 Mendix 2026-04-15 5.3 Medium
A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.17.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions < V10.12.11 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions < V10.6.19 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions < V8.18.33 only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions < V9.24.31 only if the basic authentication mechanism is used by the application). The authentication mechanism of affected applications contains an observable response discrepancy vulnerability when validating usernames. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames.
CVE-2023-52891 1 Siemens 6 Simatic Energy Manager Basic, Simatic Energy Manager Pro, Simatic Ipc Diagbase and 3 more 2026-04-15 5.3 Medium
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server.
CVE-2026-27664 1 Siemens 2 Cpci85 Central Processing\/communication, Sicore Base System 2026-04-14 7.5 High
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.10), SICORE Base system (All versions < V26.10.0). The affected application contains an out-of-bounds write vulnerability while parsing specially crafted XML inputs. This could allow an unauthenticated attacker to exploit this issue by sending a malicious XML request, which may cause the service to crash, resulting in a denial-of-service condition.
CVE-2026-27663 1 Siemens 2 Cpci85 Central Processing\/communication, Rtum85 rtu Base 2026-04-14 6.5 Medium
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.10), RTUM85 RTU Base (All versions < V26.10). The affected application contains denial-of-service (DoS) vulnerability. The remote operation mode is susceptible to a resource exhaustion condition when subjected to a high volume of requests. Sending multiple requests can exhaust resources, preventing parameterization and requiring a reset or reboot to restore functionality.
CVE-2020-26147 5 Arista, Debian, Linux and 2 more 15 C-65, C-65 Firmware, C-75 and 12 more 2026-04-14 5.4 Medium
An issue was discovered in the Linux kernel 5.8.9. The WEP, WPA, WPA2, and WPA3 implementations reassemble fragments even though some of them were sent in plaintext. This vulnerability can be abused to inject packets and/or exfiltrate selected fragments when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used.
CVE-2023-44373 1 Siemens 142 6ag1206-2bb00-7ac2, 6ag1206-2bb00-7ac2 Firmware, 6ag1206-2bs00-7ac2 and 139 more 2026-04-14 9.1 Critical
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.
CVE-2022-36325 1 Siemens 180 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 177 more 2026-04-14 6.8 Medium
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.
CVE-2022-36324 1 Siemens 168 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 165 more 2026-04-14 7.5 High
Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.
CVE-2022-36323 1 Siemens 180 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 177 more 2026-04-14 9.1 Critical
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.
CVE-2022-31765 1 Siemens 372 6ag1206-2bb00-7ac2, 6ag1206-2bb00-7ac2 Firmware, 6ag1206-2bs00-7ac2 and 369 more 2026-04-14 8.8 High
Affected devices do not properly authorize the change password function of the web interface. This could allow low privileged users to escalate their privileges.
CVE-2020-26145 3 Redhat, Samsung, Siemens 27 Enterprise Linux, Galaxy I9305, Galaxy I9305 Firmware and 24 more 2026-04-14 6.5 Medium
An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WEP, WPA, WPA2, and WPA3 implementations accept second (or subsequent) broadcast fragments even when sent in plaintext and process them as full unfragmented frames. An adversary can abuse this to inject arbitrary network packets independent of the network configuration.