| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Dozer improperly uses a reflection-based approach to type conversion, which might allow remote attackers to execute arbitrary code via a crafted serialized object. |
| Versions of MCollective prior to 2.10.4 deserialized YAML from agents without calling safe_load, allowing the potential for arbitrary code execution on the server. The fix for this is to call YAML.safe_load on input. This has been tested in all Puppet-supplied MCollective plugins, but there is a chance that third-party plugins could rely on this insecure behavior. |
| Csrf.cs in NancyFX Nancy before 1.4.4 and 2.x before 2.0-dangermouse has Remote Code Execution via Deserialization of JSON data in a CSRF Cookie. |
| In PHP before 5.6.31, an invalid free in the WDDX deserialization of boolean parameters could be used by attackers able to inject XML for deserialization to crash the PHP interpreter, related to an invalid free for an empty boolean element in ext/wddx/wddx.c. |
| CrushFTP 8.x before 8.2.0 has a serialization vulnerability. |
| Remote Code Execution is possible in Code42 CrashPlan 5.4.x via the org.apache.commons.ssl.rmi.DateRMI Java class, because (upon instantiation) it creates an RMI server that listens on a TCP port and deserializes objects sent by TCP clients. |
| Deserialization of Untrusted Data in jeecgFormDemoController in JEECG 4.0 and earlier allows attackers to run arbitrary code via crafted POST request. |
| The SolarWinds Security Event Manager was susceptible to Remote Code Execution Vulnerability. This vulnerability allows an unauthenticated user to abuse SolarWinds’ service, resulting in remote code execution. |
| The system tool has inconsistent serialization and deserialization. Successful exploitation of this vulnerability will cause unauthorized startup of components. |
| Rockwell Automation Connected Components Workbench v12.00.00 and prior does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited. |
| Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited |
| The affected Cognex product, the In-Sight OPC Server versions v5.7.4 (96) and prior, deserializes untrusted data, which could allow a remote attacker access to system level permission commands and local privilege escalation. |
| Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Deserialization of Untrusted Data vulnerability. ISaGRAF Workbench does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in ISaGRAF Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited. |
|
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution.
|
| MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 has a deserialization function that does not validate or check the data, allowing arbitrary classes to be created. |
| Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier components contain .NET remoting endpoints that deserialize untrusted data without sufficiently verifying that the resulting data will be valid. This vulnerability may allow a remote, unauthenticated attacker to gain full access to the FactoryTalk AssetCentre main server and all agent machines. |
| A deserialization vulnerability exists in how the AosService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre. |
| A deserialization vulnerability exists in how the ArchiveService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre. |
| A deserialization vulnerability exists in how the LogService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre. |
| The affected products are vulnerable of untrusted data due to deserialization without prior authorization/authentication, which may allow an attacker to remotely execute arbitrary code. |